-40%
Digital Manifold Gauge HVAC Refrigeration Vacuum Pressure Leak Tester Tool Set
$ 73.91
- Description
- Size Guide
Description
AUTOOL LM120+ Digital Refrigeration Manifold is an auxiliary instrument for the installation, testing, and maintenance of refrigeration equipment such as air conditioners and cold storage. The instrument is capable of double pressure test, dual temperature test (need test clip, not include), digital readout, multi-unit switching, multi-mode function, and built-in refrigerant database.Store category
Sign Up Now !
You may also like
AUTOOL LM120+ Digital Manifold Gauge HVAC Refrigeration Vacuum Pressure Leak Tester Tool Set
Product Description
Description:
AUTOOL LM120+ Digital Refrigeration Manifold is an auxiliary instrument for the installation, testing, and maintenance of refrigeration equipment such as air conditioners and cold storage. The instrument is capable of double pressure test, dual temperature test (need test clip, not include), digital readout, multi-unit switching, multi-mode function, and built-in refrigerant database.
Feature:
1.
Type Setting&Observable Window
: AUTOOL LM120+ Digital Refrigeration Manifold can be set according to the type of refrigerant that the car needs to fill; The refrigerant filing status can be observed through a visible window.
2.
Smart Digital Display
: The intelligent digital display of the test results of the pressure and temperature of the air conditioning system reduces the cost of time.
3.
3 Years Warranty, Lifetime Maintenance
: For damage caused by non-human factors, AUTOOL promises to resend parts for free within 3 years. For any needs, you are warmly welcomed to contact us and we will get back to you ASAP within 24 hours.
Function:
1.
Evaporation Pressure &
Temperature
Test
: The maximum pressure when the refrigerant changes from liquid to gas. The lowest temp when the liquid becomes gaseous.(The lower the pressure and temp of the evaporation are, the more efficient the refrigeration cycle and the greater the refrigeration capacity will do.)
2.
Condensing Pressure &
Temperature
Test
: The minimum pressure when the refrigerant changes from gas to liquid, and the maximum temp when the gas changes to liquid. (The lower the pressure and temp of condensation are, the higher the efficiency of the refrigeration cycle and the greater the refrigerant capacity will do.)
3.
High/Low-pressure Temperature Test
: The temperature of the AUTOOL LM120+ Digital Refrigeration Manifold in the high/low-pressure pipelines of the air conditioning system.
4.
Pressure Leakage Test
: Calculate the pressure difference between the initial test pressure and the second test pressure to determine if the refrigerant is leaking.
Specification:
Pressure Test:Gauge Pressure
Pressure Test Unit:Kpa; Mpa; bar; inHg; PSI.
Pressure Test Range:0 Kpa ~ 6000 Kpa
Pressure Test Resolution:1Kpa
Pressure Test Accuracy:+/- 0.5 %(FS)+ 5dgt
Pressure Overload Limit:10000 Kpa (10 Mpa; 100 bar;)
Vacuum Test:Relative Vacuum
Vacuum Test Unit:Kpa; Mpa; bar; inHg; PSI.
Vacuum Test Range: -101Kpa ~ 0Kpa
Vacuum Test Resolution: 1Kpa
Temperature Test Unit: °C (Celsius), °F (Fahrenheit)
Temperature Test Range: -40°C ~ 150°C (-40°F ~ 302°F)
Temperature Test Resolution:
*0.1°C (-40°C ~ 99.9°C),1°C (100°C ~ 150°C)
*0.1°F (-40°F ~ 99.9°F),1°F (100°F ~ 302°F)
Safety Standards For Design And Production:
1.The pressure measured by the digtal manifold pressure tester is gauge pressure.
2.Pressure testing ranges from -101Kpa to 6Mpa (-0.1bar to 60bar).
3.The limit pressure is 10 Mpa (100 bar).
4.The maximum operating pressure of standard hose is 600 PSI ( approximate 4.13 Mpa, 41.3 bar ). The limit pressure is 3000 PSI approximate 20.68 Mpa, 206.8 bar ).
5.Please confirm the rated pressure value of the tested equipment before testing. Do not use it if it exceeds the range of the instrument. Also for DY517A, if the packed hoses does not match the pressure requirement, you can use suitable replacements for testing.
6.Do not use and store the instrument in high temperature, high humidity, flammable, explosive and strong electromagnetic fields.
7.Please do not change the instrument internal circuit, to avoid any damage of the instrument or danger occurring.
8.Please wear qualified protective equipment to protect user during testing.
9.Please use the instrument in a well-ventilated environment to prevent inhalation of toxic gases.
Packing List:
1 PC* AUTOOL LM120 Digital Refrigeration Manifold Main Unit.
1 PC* User Manuel.
2 PCS* Temperature Clip.
3 PCS* Test Pipe.
Payment
Delivery details
Terms of sales
About us
Contact us
Payment
1. We accept PayPal only.
2. Credit card (Visa, Eurocard/MasterCard, Amex, and Switch or Visa/Delta) payment can be accepted ONLY through PayPal (You don't need a PayPal account)!
3. Other payment methods (Bank transfer, Cheque, etc.) are NOT acceptable !
4. Please make the payment within 3 days.
Delivery details
1. Nowadays, you can meet AUTOOL on every continent and in 160 countries around the world.
2. Item will be shipped out within 1-5 working days (except weekends and holidays) after the payment is cleared or received.
3. We will send item to your Confirmed Shipping Address in Paypal only.Please confirm your order and address before you bid or pay the item.
4.International Buyers Please Note:
1) Please check with your country customs office to determine what these additional Import tariffs costs will be prior to bidding / buying.
2) It's the buyer's responsibility to complete clearance when parcel reached your Customs. We are Not responsible for buyers's local taxes, please consult local Customs for Tax Details. Customs rates vary from country to country, please understand.
5. Any further queries, please don't hesitate to email us. Thank you.
Terms of sales
1.Our Service:
From the date of receipt, we provide a
3-YEAR WARRANTY
for the main unit and all the accessories included.
2.Warranty Access:
(1)The repair or replacement of products is determined by the actual breakdown situation of product.
(2)It is guaranteed that AUTOOL will use brand new component, accessory or device in terms of repair or replacement.
(3)If the product fails within 90 days after the customer receives it, the buyer should provide both video and picture.While the product is received for more than 90 days, the customer will bear the appropriate cost and we will provide the parts to the customer for replacement free of charge.
3.These Conditions Below Shall Not Be In Warranty Range:
The product breakdown because the user does not follow product instructions to use or maintain the product.
About us
1.Our Story
:
AUTOOL was founded in 2014 in Shenzhen, China, inspired by a group of vehicle enthusiasts. They have been in the field of car repair tools for more than ten years, dreaming of a simpler and more efficient solution for car repair!
2.Our Products
:
Product development, quality control,and customer service are always highest on our list of priorities. Moreover, we will launch premium new products persistently, with patented technologies and innovative ideas embedded in.
3.Our Vision:
We are always responsible for our products, responsible for our customers and responsible for our partners. We aspire to be an outstanding and competitive supplier of automotive tools, providing the customers with affordable and high-quality products.
Contact us
1. If you have any further queries, you can feel free to email me via email or eBay message. Thank you.
2.
Please email us first before giving negative feedback or opening a case.
Wish we can solve the problem peacefully.
3. Much appreciated if you could leave us positive feedback with five stars.
4. We will reply you within 12 hours and do our best solve the problem with you (Except on Weekends and Holidays).
5. Work Time:
Monday to Friday GMT8 (9:00am-18:00 PM)
.
Feedback